Notes:
|
- Thermal lock automatically locks inactive door under high fire/heat conditions
- 280X dust proof strikes are recommended for use with these sets
- 1-1/2 hour fire rated for wood doors up to 4 feet wide by 9 feet tall
- Used in pairs at top and bottom of inactive door
- Fully automatic - bolts retract when active door is opened; bolts extend when active door is closed
- Non-handed
- Bolt head rods are adjustable
|
Automatic Flush Bolt Set
For Wood Covered Composite Doors
Flush Bolts & Coordinating Devices
Faceplate:
|
- 1'' x 8-1/2'' (25 mm x 216 mm)
|
Flattened Round Bolt Head:
|
- 1/2" (13 mm)
|
Bolt Throw:
|
- 3/4" (19 mm)
|
Materials:
|
- Stainless steel and brass with steel components
|
Finishes:
|
- US3, US4, US10, US10B, US15, US32, US32D
|
Fasteners:
|
- Three (3) #10 x 1" SMS
- Six (6) #8 x 1" combo screws
- Two (2) plastic anchors
|
Mortise Strike:
|
- 15/16" x 2-1/4" (24 mm x 57 mm)
|
Bolt Backset:
|
- 3/4" (19 mm)
|
- B, C, D, and E Label
- ANSI A156.3 Type #25
|
Description | File Number |
Installation Instructions | I-TA01032 |