Application: |
-Airport & Public Facility Security and Safety
- Loss Prevention
- Restrict the egress of wandering patients
- Restrict the egress of commercial center patrons for security
|
Operation: |
- Typically used on exit doors when unauthorized egress is initiated when in the
locked mode.
- The door unlocks after 15 seconds permitting egress
- SVR exits must include rod covers
- Door position switch (DPS) is recommended
- Exit device cannot be cut down once the OnBoard Delayed Egress modification has been made to the device.
|
Note: |
- Requires Mortise Cylinder, sold separately
(1-1/8" - 1 3/8" length, 3978 Cloverleaf or equivalent tailpiece required.) |
4501 Onboard Delayed Egress (OBDE)
Features: |
- 15 (or optional 30) second egress delay
- 1 or 2 second nuisance delay
- Built-in function keypad provides alarm and lock reset. 1 to 30 second bypass, sustained bypass and additional keyswitch
- Control inputs include 1 to 30 second request to exit and access bypass with
anti-tailgate and alarm rest
- Field selectable trigger modes from exit device (N/O or N/C)
- Field selectable automatic or manual power up after emergency release or power loss
|
Built-In Annunciation: |
- Armed mode
- Nuisance mode
- Irreversible egress mode
- Release mode |
Code Compliance: |
- IFC International
- IBC International Building Code
- NFPA 101 Life Safety Code
- NFPA 1 Uniform Fire Code
- California Building Code |
Voltage Input: |
- 24VDC |
Reset Input: |
- N/O, Dry input |
Rex Input: |
- N/O, Dry input |
Bypass Input: |
- N/O, dry input |
Monitoring Outputs: |
- Alarm relay - 1 amp @30VDC SPDT, Dry
- Door security relay - 1 amp @30VDC SPDT, Dry
- Secure/insecure status
- Egress initiation status
- Released/bypass status |
Control Inputs: |
- Field selectable 1-30 second request to exit with anti-tailgate and door prep
alarm
- Bypass
- Reset
- Remote trigger (for pairs of doors)
- DPS (required for door forced, prop, and anti-tailgate)
|
Finishes: |
- US3, US3, US10, US10B, US26, US26D, US32D, BLK |
|
|
|
|