4501/4601 DE

Application: - Airport & Public Facility Security and Safety
- Loss Prevention
- Restrict the egress of wandering patients for safety
- Restrict the egress of commercial center patrons for security

Operation: - Typically used on exit doors when unauthorized egress is initiated when in the locked mode
 - The door unlocks after 15 seconds permitting egress
- SVR exits must include rod covers
- Door position switch (DPS) is recommended

Note: - Wall controller 2-679-0630 sold separately 
Delayed Egress
DateDescriptionDownload

Features: - 15 (or 30) second egress delay
- 1 or 2 second nuisance delay
- Built-in function keypad provides alarm and lock reset, 1 to 30 second bypass, sustained bypass, and additional keyswitch
- Control inputs include 1 to 30 second request to exit and access bypass with anti-tailgate and alarm rest
- Field selectable trigger modes from exit device (N/O or N/C)
- Field selectable automatic or manual power up after emergency release or power loss

Built-in annunciation: - Armed mode
- Nuisance mode
- Irreversible egress mode
- Release mode
- Digital countdown display
- Field selectable vice notification or tone
- Field selectable male or female voice

Code Complaince: - IFC International
- IBC International Building Code
- NFPA 101 Life Safety Code
- NFPA 1 Uniform Fire Code
- California Building Code

Electrical Specs:

- Voltage Input:
   • Single 430 mA @ 24VDC
   • Tandem 680 mA @ 24VDC
- Reset input: N/O, Dry input
- Rex input: N/O, Dry input
- Trigger: N/C, Dry input
- DPS input: N/O, Dry input

Monitoring Outputs: - Secure / Insecure status
- Egress initiation status
- Released / Bypass status
- Alarm relay - 1 amp @ 30VDC SPDT, Dry
- Door security relay - 1 amp @30VDC SPDT, Dry

Finishes: - US3, US4, US10, US10B, US26, US26D, US32D, BLK

DescriptionFile Number
4500 Series with Rim Cylinder TemplateT-ED00862-Template
DescriptionFile Number
Wire Routing/Door Prep InstructionsI-ED00367-Rev9
4501/4601 Installation InstructionsI-EA00052
DescriptionFile Number
DescriptionFile Number
Previous Next