4500 Series CVR Less Bottom Rod
Application:
|
- Heavy duty commercial
- NOT recommended with Single-Rabbet Double Egress frames
- NOT recommended for doors with inset greater than 1/8"
|
Certifications: |
- ANSI/BHMA A156.3-2014 Grade 1
- UL305 Listed for Panic Hardware
- UL/cUL Listed for up to 3 hours for "A" label doors
- UL10C Positive Pressure Rated
- UL10B Neutral Pressure Rated
- Complies with ANSI A117.1 for accessible buildings and facilities
|
Grade 1 Concealed Vertical Rod Less Bottom Rod
4500 Series - Grade 1
Trim:
|
- Archer, August, William or Withnell lever with escutcheon trim
- Pull plate trim (excluding 45PT)
- Rim cylinder x optional pull
|
Covers:
|
- Stainless steel, zinc
|
Cover Tube:
|
- Aluminum
|
End Caps:
|
- Zinc
|
Door Width:
|
- 36'' (914 mm) field sizeable to 30'' (762 mm) panic-rated door and 28" (711 mm) fire-rated door
- 48'' (1219 mm) field sizeable to 36'' (914 mm) panic- or fire-rated door
- Reference electrified exit device for door width specifications
|
Door Height:
|
- 7' (2134 mm) - Standard
- 8' (2438 mm) - Optional
- 10' (3048 mm) - Optional (panic device only)
|
Door Thickness:
|
- 1-3/4" (44 mm) - standard
|
Projection: |
- 3" (76 mm) in undogged position
- 2-5/8" (67 mm) in dogged position
|
Stile Width:
|
- 4" (102 mm) minimum stile width required
- All stile widths are measured from door edge
|
Fasteners:
|
- Wood and machine screws
- Thru-bolts
|
Rod Length: |
- Rods for 7' (2134 mm) door - Standard
- Rods for 8' (2438 mm) and 10' (3048 mm) doors - Optional
- Door height of 7' (2134 mm) requires 34-5/8" (879 mm) top rod length
- Door height of 8' (2438 mm) requires 46-5/8" (1184 mm) top rod length
- Extension rod kits available, 2' (610 mm) or 3' ( 914 mm) |
Latchbolt:
|
- Top - 1/2" (13 mm) throw, pullman type with automatic dead latching, stainless steel
|
Strikes:
|
- Stainless steel with plated rollers included standard with panic devices
- Solid stainless steel included standard with fire rated devices
- Top strike mortised into frame
- Double door strike for use with CVR and RIM device available
|
Finishes:
|
- US3, US4, US10, US10B, US26, US26D, US32D, BLK
- Trim not available in US32D
|
Dogging:
|
- Hex key dogging standard on panic-rated devices
- Cylinder dogging is available on panic-rated devices only, specify CD (3902 mortise cylinder with standard cam is sold separately)
|
Notes:
|
- Center line prep is 40" (1016 mm) - If door prep elevation is lower, a longer top rod will need to be ordered
- Recommended to be used on appropriately reinforced doors
- A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device's fire rating.
|
EPD: |
- 4500 Exit Device Environmental Product Declaration
|