Trim: |
- Escutcheon trim
- Pull plate trim
|
Covers: |
- Stainless steel, zinc
|
Cover Tube: |
- Aluminum
|
End Caps: |
- Zinc
|
Door Width: |
- 36" (914 mm) field sizeable to 30" (762 mm) panic-rated door and 28" (711 mm) fire-rated door for devices with any monitoring switches
- 48" (1219 mm) field sizeable to 36" (914 mm) panic- or fire-rated door for devices with any monitoring switches
- 36” (914 mm) field sizeable to 34” (864 mm) door minimum for devices with motorized electric latch retraction.
- 36” (914 mm) door minimum for devices with electric dogging, alarm kit, delayed egress or onboard delayed egress.
- 48” (1219 mm) field sizeable to 42” (1067 mm) door minimum for devices with electric dogging or alarm kit.
- 48” (1219 mm) field sizeable to 40” (1016 mm) door minimum for devices with motorized electric latch retraction.
- 48” (1219 mm) door minimum for devices with delayed egress or onboard delayed egress.
|
Door Thickness: |
- 1-3/4" (44 mm) - standard up to 3", except with night latch which is 2-1/2"
|
Stile Width: |
- 5-3/8" - Min. stile width required for single doors and standard 5/8" stop
- 5-3/4" - Min. stile width required for double doors and 2" mullion
- 4-7/8" - Min. stile width required for double doors
- All stile widths are measured from door edge
|
Fasteners: |
- Wood and machine screws
- Thru-bolts
|
Latchbolt: |
- 3/4" throw
- Stainless Steel with dead latch
|
Strikes: |
- Steel with plated rollers - Standard
- Overlapping strike for pair of doors
- Surface applied to frame with slotted holes for easy adjustment
- Fire rated strike for use with mullions
|
Finishes: |
- US3, US4, US10, US10B, US26, US26D, US32D, BLK
- Trim is not available in US32D
|
Function: |
- ED - Electric Dogging
- RX - Request to Exit
- EDRX - Electric Dogging with Request to Exit
- ALK - Alarm Kit
- AI - Authorized Ingress
- LM - Latch Bolt Monitor
- MLR - Motor Driven Electric Latch Retraction (Field Installation Kit 2-649-5007)
- MLRX - Motor Driven Electric Latch Retraction with Request to Exit
- DE - Delayed Egress
|
Electrical Specifications: |
- ED; .225 AMP @ 24 Volt +/- 2 V
- RX, LM or AI; 125 VAC (3 AMP current); 30 VDC (2 AMP current)
- ELR; requires 2901/2902 power supply
- MLR; 1 AMP in rush @ 24 VDC +/- 2 V
- DE; 430mA @ 24V Single; 680mA @ 24V Tandem
|
Wire Requirements: |
- EL and EU functions require 2 wires for power per device
- Status switches (i.e. RX, LM, etc.) require 2 wires per switch to monitor a normally open (NO) or normally closed (NC) position
- All devices provide 3 wires per switch so both NO and NC positions can be monitored
- Monitoring both positions will require 3 wires per switch
|
Quick Connect:
|
- Available on AI, ED, LM, MLR, and RX. Compatible with Hager Quick Connect Harness Cables which can plug into Hager hinges with quick connect for quick and accurate wiring of the door. |
Warranty: |
- One-year on electrified components
- Lifetime on hardware components
|